Dimensions in mm
Flow & Pressure

The supplied flow and pressure to the MP-F are dependant on the intensification ratio chosen. The table below shows the flow and pressure for each model. Flow Q1 is when the pump pressure has been reached, and flow Q2 is when moving up the vertical part of the pressure curve. For information on the flow-pressure curve press Function

Ratio Inlet Flow (max.)

(LPM / GPM)

Outlet Flow Q1

(LPM / GPM)

Outlet Flow Q2

(LPM / GPM)

Inlet Pressure (max.)

(Bar / Psi)

Outlet Pressure

(Bar / Psi)

2.0 8.0 / 2.1 0.8 / 0.21 0.2 / 0.08 200 / 2,900 400 / 5,800
3.4 15.0 / 4.0 2.2 / 0.58 0.5 / 0.13 200 / 2,900 680 / 9,860
4.0 14.0 / 3.7 1.8 / 0.47 0.4 / 0.10 175 / 2,538 700 / 10,150
5.0 14.0 / 3.7 1.4 / 0.37 0.3 / 0.08 140 / 2,030 700 / 10,150
7.0 13.0 / 3.4 1.1 / 0.29 0.2 / 0.05 100 / 1,450 700 / 10,150

The MP-F pressure intensifier is a flange-on model, designed to be mounted onto a hydraulic block. The MP-F will increase a supplied pressure to the higher end pressure required (max. 700 Bar / 10,150 psi). Having all high pressure valves incorporated, including the POV, a pilot operated check valve, for relieving the high pressure side, the MP-F offers a cost effective solution for intensifiction needs. Conrolling the high pressure side is done by valves on the low pressure side through the MP-F, allowing the MP-F to be installed in most new and existing hydraulic circuits. The MP-F intensifier is offered with 5 different intensification ratios as standard with additional ratios on request to meet most intensification requirements. For more information on the POV check valve press Function

Home

Pressure Intensifiers

Applications

Hydraulic Circuits

Contact

    The MP-F

          Pressure Intensifier