| Ratio |
Inlet Flow (max.) (LPM / GPM) |
Outlet Flow Q1 (LPM / GPM) |
Outlet Flow Q2 (LPM / GPM) |
Inlet Pressure (max.) (Bar / Psi) |
Outlet Pressure (Bar / Psi) |
| 1.5 | 8.0 / 2.1 | 0.8 / 0.21 | 0.3 / 0.08 | 200 / 2,900 | 300 / 4,350 |
| 2.0 | 8.0 / 2.1 | 0.8 / 0.21 | 0.2 / 0.08 | 200 / 2,900 | 400 / 5,800 |
| 3.4 | 15.0 / 4.0 | 2.2 / 0.58 | 0.5 / 0.13 | 147 / 2,132 | 500 / 7,250 |
| 4.0 | 14.0 / 3.7 | 1.8 / 0.47 | 0.4 / 0.10 | 125 / 1,812 | 500 / 7,250 |
| 5.0 | 14.0 / 3.7 | 1.4 / 0.37 | 0.3 / 0.08 | 100 / 1,450 | 500 / 7,250 |
| 7.0 | 13.0 / 3.4 | 1.1 / 0.29 | 0.2 / 0.05 | 71 / 1,036 | 500 / 7,250 |
| 9.0 | 13.0 / 3.4 | 0.7 / 0.19 | 0.1 / 0.03 | 56 / 806 | 500 / 7,250 |
![]()
![]() |
![]() |
The supplied flow and pressure to the MP-C are
dependant on the intensification ratio chosen. The table below shows the
flow and pressure for each model. Flow Q1 is when the pump pressure has been
reached, and flow Q2 is when moving up the vertical part of the pressure
curve. For information on the flow-pressure curve press
![]()

The MP-C is an CETOP DO3 /
NG6
hydraulic pressure intensifier designed to be positioned in a low pressure
hydraulic system, and will provide higher pressure exactly where needed
(max. 500 bar / 7,200 psi). Having all the required high pressure valves
integrated, including the POV, a pilot operated check valve for relieving te
high pressure side, the MP-C intensifier offers a cost effective solution
for intensification needs in a CETOP system. Control of the high pressure side is
achieved by valves on the low pressure side through the intensifier, which
adds to safety. The MP-C intensifiers are offered with 7 different
intensification ratios as standard, with additional ratios available on
request to meet most intensification requirements. For more information on
the POV press
![]()
|
The MP-C Pressure Intensifier |
![]()
![]()